Servicing All 32 London Boroughs, Hertfordshire & Bedfordshire NAPIT Registered #67518 0% VAT on Solar & Battery (Until March 2027)
NAPIT Registered Contractor #67518

Domestic & Commercial Electrical Services

From modern RCBO consumer unit upgrades and Type 1+2 surge protection (SPD) to full property rewires and EICR safety testing. Fully certified, insured and compliant with 18th Edition BS 7671 regulations.

NAPIT #67518
Part P Approved Contractor

Why NAPIT Accreditation Protects You

  • Building Regulations Sign-Off: We self-certify our electrical work directly to your local council building control, saving you hundreds in inspector fees.
  • Annual Technical Vetting: Our equipment calibration, test instruments, and on-site installations undergo rigorous annual inspection.
  • Workmanship Guarantee: Backed by NAPIT's consumer protection guarantee and £5,000,000 public liability insurance.

Electrical Services We Deliver

All work includes formal electrical installation certificates (EIC) or minor works certificates logged onto the national Part P database.

Consumer Unit Upgrades

Replace dangerous old fuse wire boxes with a metal fire-rated 18th Edition dual-RCD or full RCBO board with surge protection.

Free Visual Survey & Written Estimate

Surge Protection (SPD)

Type 1+2 surge protection devices protecting televisions, computers, heat pumps and solar inverters from transient voltage spikes.

Comprehensive Transient Surge Defense

Full & Partial Rewiring

Complete property rewiring for refurbishments and period homes using LSZH / twin & earth cabling with new sockets, switches and lighting.

Detailed Fixed-Price Specification

EICR Safety Inspections

Electrical Installation Condition Reports for landlords, buyers and home movers. Comprehensive testing of insulation resistance and earth loops.

Fixed-Fee Landlord & Domestic Reports

Smart Meter Isolation

Installation of double pole 100A main isolation switches allowing clean smart meter upgrades and solar PV interconnects without DNO delays.

Certified Isolation Switch Fitting

Fault Finding & Repairs

Expert diagnosis of tripping RCDs, burnt terminals, dead sockets and intermittent electrical issues using calibrated test equipment.

Transparent Diagnostic Callout Terms

Consumer Unit Boards We Supply & Fit

We install metal, non-combustible consumer units from the UK's most trusted manufacturers. Every board is fitted with individual RCBO circuit protection to prevent whole-house blackouts.

Heavy Commercial Grade Reliability
Verified Install • Wantage

Eaton (MEM) Memshield 3

Eaton's Memshield range is the benchmark in commercial and domestic electrical distribution. Solid steel construction, high breaking capacity and exceptional terminal spacing for clean, heat-dissipating wiring.

  • Full RCBO Protection: A fault on one socket circuit trips only that specific breaker — never plunges your house into darkness
  • Integrated SPD: Factory-fitted Type 2 surge arrester protecting all sensitive home electronics
  • Solar Ready: Dedicated bidirectional breakers designed for solar and battery feedback currents
Installed Upgrade Price
Bespoke Specification (Fully Certified)
10-Year Eaton Warranty
Eaton consumer unit board
Arc Fault Detection (AFDD) Specialist

Schneider Electric Acti9

Schneider Acti9 boards offer cutting-edge Arc Fault Detection Devices (AFDD) that detect dangerous electrical arcing behind walls before an electrical fire can ignite. Recommended for high-risk properties and timber frame builds.

  • AFDD Fire Safety: Microprocessor analysis detects parallel and series arc faults instantly
  • VisiTrip Indicator: Instant visual window shows tripped faulty circuit at a glance
  • Modular Space: Extra DIN rail capacity for future EV charger and heat pump additions
Installed Upgrade Price
Bespoke Specification (Fully Certified)
10-Year Schneider Guarantee
Schneider consumer unit
Clean Domestic Aesthetic
Verified Install • Hertfordshire

Hager Design 10 / VML

Hager consumer units are renowned among UK electricians for their generous cabling space, flush aesthetic cover and top-mounted cable entry knockouts. Finished in clean signal white powder coat.

  • Fire-Rated Steel: Complies fully with BS 7671 Amendment 3 non-combustible enclosure requirements
  • Pre-Wired SPD: Built-in Type 2 surge cartridge with replaceable plug-in module
  • Neat Presentation: Magnetic catch door keeps breakers discreetly concealed
Installed Upgrade Price
Bespoke Specification (Fully Certified)
10-Year Hager Warranty
Hager Design 10 18th Edition metal consumer unit with Type A RCDs and SPD

Electrical Case Studies: The Whole Installation Process

From safe electrical isolation and metal consumer unit replacements to continuous dMEV ventilation, see our certified electrical work documented step by step.

Consumer Unit & Switchgear Wantage, Oxfordshire OX12 • 18th Edition Consumer Unit & SPD Upgrade

18th Edition Amendment 2 RCBO Metal Consumer Unit & Type 2 SPD Upgrade

BS 7671 Amendment 2 • EICR Certified
STAGE 01 Service Intake & Safe Isolation
Conducted safe electrical isolation at the DNO cut-out. Verified earth loop impedance (Ze) and prospective fault current (PFC) across domestic sub-circuits prior to consumer unit changeover.
STAGE 02 18th Edition Metal Board Wiring
Installed a non-combustible steel FuseBox consumer unit with integrated Type 2 Surge Protection Device (SPD), 100A double-pole main switch, and individual bi-directional RCBO protection for all power and lighting rings.
STAGE 03 Testing, Handover & Certification
Conducted full dead and live tests using calibrated multi-function testers. Verified RCD trip times at 1x and 5x IΔn, recorded insulation resistance (>200MΩ), and issued official NAPIT Part P Certification.
Commercial & Domestic Sub-Distribution Hertfordshire • Heavy-Duty Power Sub-Distribution

Precision Commercial Distribution Board Upgrade with Eaton & Schneider Switchgear

18th Edition • High-Integrity Busbar
STAGE 01 Enclosure & Cable Containment
Mounted heavy-duty Eaton metal-clad commercial distribution enclosures with top and bottom galvanised trunking containment, engineered to manage multi-phase sub-mains and auxiliary power supplies.
STAGE 02 Precision Busbar & Surge Suppression
Installed high-integrity copper busbar distribution with dedicated Type 1+2 surge protective devices, protecting sensitive commercial equipment against lightning transients and grid over-voltages.
STAGE 03 Multi-Way Sub-Board Handover
Completed final circuit terminations on Schneider multi-way switchgear. Applied calibrated torque verification to all terminals, verified circuit balance, and completed periodic inspection reporting.

Electrical Services FAQs

Important advice regarding consumer unit replacement, building regulations and electrical safety.

Since the 2016 introduction of BS 7671 Amendment 3, all new domestic consumer units must be manufactured from non-combustible materials (heavy steel) to contain potential electrical fires. Older plastic units with rewireable fuses also lack vital 30mA RCD shock protection and surge protection.
Yes, the electricity supply will be isolated for approximately 3 to 5 hours while the new board is mounted, cables routed, and circuit testing completed. We provide full notice in advance and restore power as quickly as possible.
Upon completion of any notifiable work, you receive an Electrical Installation Certificate (EIC) complete with a schedule of circuit test results, alongside a formal NAPIT Building Regulations Compliance Certificate mailed directly to your home.

Book Your Free Site Survey

Speak directly to our certified electrical engineers. We visit your property, assess your roof/electrical installation, and provide an itemized proposal with zero obligation.

Operating Base
Watford, Hertfordshire & Greater London
Accreditation
NAPIT Registered Contractor #67518

Request Survey Callback

Fast response within 2 hours. Your information is protected and never sold.